SIMULATION OF GAS DYNAMICS IN A SUBJECT BREATHING VIA SELF-CONTAINED SELF-RESCUE APPARATUS Full article
| Journal |
Romanian Journal of Physics
ISSN: 1221-146X |
||
|---|---|---|---|
| Output data | Year: 2020, Volume: 65, Number: 4, Article number : 704, Pages count : 12 | ||
| Tags | alveolar gas exchange; mathematical modeling; self-contained breathing apparatus | ||
| Authors |
|
||
| Affiliations |
|
Abstract:
Self-contained self-rescue (SCSR) breathing devices are the only option for providing breathable air if hazardous components cannot be removed from external air after underground accidents. In this study, we developed a mathematical model of human breathing with an SCSR apparatus. The model describes the gas-content dynamics in the three system compartments: the lungs, body tissues and a SCSR apparatus. The results of simulations agreed well with experimental data obtained from a volunteer breathing through the apparatus.
Cite:
ERMOLAEV E.S.
, DYACHENKO A.I.
, SHULAGIN Y.A.
, SUVOROV A.V.
, PARSHIN K.S.
SIMULATION OF GAS DYNAMICS IN A SUBJECT BREATHING VIA SELF-CONTAINED SELF-RESCUE APPARATUS
Romanian Journal of Physics. 2020. V.65. N4. 704 :1-12.
SIMULATION OF GAS DYNAMICS IN A SUBJECT BREATHING VIA SELF-CONTAINED SELF-RESCUE APPARATUS
Romanian Journal of Physics. 2020. V.65. N4. 704 :1-12.