Sciact
  • EN
  • RU

SIMULATION OF GAS DYNAMICS IN A SUBJECT BREATHING VIA SELF-CONTAINED SELF-RESCUE APPARATUS Научная публикация

Журнал Romanian Journal of Physics
ISSN: 1221-146X
Вых. Данные Год: 2020, Том: 65, Номер: 4, Номер статьи : 704, Страниц : 12
Ключевые слова alveolar gas exchange; mathematical modeling; self-contained breathing apparatus
Авторы ERMOLAEV E.S. 1 , DYACHENKO A.I. 1 , SHULAGIN Y.A. 1 , SUVOROV A.V. 1 , PARSHIN K.S. 1
Организации
1 Institute of Biomedical Problems RAS (IMBP) Moscow, Russian Federation

Реферат: Self-contained self-rescue (SCSR) breathing devices are the only option for providing breathable air if hazardous components cannot be removed from external air after underground accidents. In this study, we developed a mathematical model of human breathing with an SCSR apparatus. The model describes the gas-content dynamics in the three system compartments: the lungs, body tissues and a SCSR apparatus. The results of simulations agreed well with experimental data obtained from a volunteer breathing through the apparatus.
Библиографическая ссылка: ERMOLAEV E.S. , DYACHENKO A.I. , SHULAGIN Y.A. , SUVOROV A.V. , PARSHIN K.S.
SIMULATION OF GAS DYNAMICS IN A SUBJECT BREATHING VIA SELF-CONTAINED SELF-RESCUE APPARATUS
Romanian Journal of Physics. 2020. V.65. N4. 704 :1-12.
Идентификаторы БД: Нет идентификаторов
Цитирование в БД: Пока нет цитирований