Sciact
  • EN
  • RU

The neutron dose equivalent rate measurements by R3DR/R2 sp ectrometers on the international space station Научная публикация

Журнал Life Sciences in Space Research
ISSN: 2214-5532 , E-ISSN: 2214-5524
Вых. Данные Год: 2023, Том: 39, Страницы: 43-51 Страниц : 9 DOI: 10.1016/j.lssr.2023.01.001
Ключевые слова Space radiation; Neutron dose equivalent rate; ISS; Solar cycle variations
Авторы Dachev Tsvetan P. 1 , Litvak Maxim L. 2 , Benton Eric 3 , Ploc Ondrej 4 , Tomov Borislav T. 1 , Matviichuk Yuri N. 1 , Dimitrov Plamen G. 1 , Koleva Rositza T. 1 , Jordanova Malina M. 1 , Bankov Nikolay G. 1 , Mitev Mityo G. 1 , Mitrofanov Igor G. 2 , Golovin Dmitri V. 2 , Mokrousov Maxim I. 2 , Sanin Anton B. 2 , Tretyakov Vladislav.I. 2 , Shurshakov Viacheslav A. 5 , Benghin Victor V. 5
Организации
1 Space Research and Technology Institute Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Block 1, 1113 Sofia, Bulgaria
2 Space Research Institute, Russian Academy of Sciences, Moscow, Russia
3 Department of Physics, Oklahoma State University, USA
4 Nuclear Physics Institute, Czech Academy of Sciences, Prague, Czech Republic
5 State Research Center Institute of Biomedical Problems, Russian Academy of Science, Moscow, Russia

Реферат: The data from two Bulgarian-German instruments with the basic name “Radiation Risk Radiometer-Dosimeter” (R3D) are discussed. The R3DR instrument worked inside the ESA EXPOSE-R facility (2009–2010), while R3DR2 worked inside the ESA EXPOSE-R2 facility (2014–2016). Both were outside the Russian Zvezda module on the International Space Station (ISS). The data from both instruments were used for calculation of the neutron dose equivalent rate. Similar data, obtained by the Russian “BTNsingle bondNEUTRON” instrument on the ISS are used to benchmark the R3DR/R2 neutron dose equivalent rate. The analisys reveals that the “BTNsingle bondNEUTRON” and R3DR/R2 values are comparable both in the equatorial and in the South Atlantic Anomaly (SAA) regions. The R3DR/R2 values are smaller than the “BTNsingle bondNEUTRON” values in the high latitude regions. The comparison with the Monte Carlo simulations of the secondary galactic cosmic rays (GCR) neutron ambient dose equivalent rates (El-Jaby and Richardson, 2015, 2016) also shows a good coincidence with the R3DR/R2 spectrometer data obtained in the equatorial and high latitude regions.
Библиографическая ссылка: Dachev T.P. , Litvak M.L. , Benton E. , Ploc O. , Tomov B.T. , Matviichuk Y.N. , Dimitrov P.G. , Koleva R.T. , Jordanova M.M. , Bankov N.G. , Mitev M.G. , Mitrofanov I.G. , Golovin D.V. , Mokrousov M.I. , Sanin A.B. , Tretyakov V.I. , Shurshakov V.A. , Benghin V.V.
The neutron dose equivalent rate measurements by R3DR/R2 sp ectrometers on the international space station
Life Sciences in Space Research. 2023. V.39. P.43-51. DOI: 10.1016/j.lssr.2023.01.001 WOS Scopus РИНЦ OpenAlex
Даты:
Поступила в редакцию: 5 авг. 2022 г.
Принята к публикации: 9 янв. 2023 г.
Опубликована online: 11 янв. 2023 г.
Опубликована в печати: 7 нояб. 2023 г.
Идентификаторы БД:
Web of science: WOS:00111025150000
Scopus: 2-s2.0-85146841765
РИНЦ: 60485264
OpenAlex: W4315641618
Цитирование в БД:
БД Цитирований
OpenAlex 6
Scopus 5
Альметрики: